Tank or Tankless? What Ten Homes Measured, and What Hard Water Does to the Answer

For most people replacing a gas tank, the measured answer is that tankless saves energy, and the saving rarely repays the extra cost quickly. A ten-home Minnesota study found 37 percent less energy for hot water and a payback of 20 to 40 years at 2010 prices. If you want unlimited hot water, that is the better reason.

Electric homes face a different choice. There the serious comparison is a heat pump tank, not a tankless unit, and the evidence below treats it separately. This article covers what to ask and what it costs, not the gas or electrical work itself, which the advisory below addresses.

The reader who asked which type is better listed four wishes: affordable, easy to maintain, reliable, and cheap to repair. The replies split between people who would never go back to a tank and people who regret leaving one. Most of them, it turned out, were describing different houses.

What Was Actually Measured

The fullest field test we found is by Bohac and colleagues at Minnesota’s Center for Energy and Environment, in 2010, with lab work at Brookhaven National Laboratory. They ran tanks and tankless units in the same ten homes.

It is one cold-climate study, it was not peer reviewed as we read it, and the units are now old.

It found “a 37% savings of water heating energy per household” from replacing a typical natural draft tank. The table sets its numbers beside the Department of Energy’s lifetime figures and a Pacific Northwest National Laboratory review. The rows rest on different evidence, so read each one with its source.

What has been measured, gas against gas

Each row names its evidence, and the rows do not share one. Costs are from 2010 and are shown for scale only.

The question Gas tank Gas tankless
Energy for hot water

Ten Minnesota homes, 2010
Baseline 37 percent less on average
Standby loss

Same study, a day with no use
16.6 kBtu a day 0.6 kBtu a day
Delay at the heater

To 95 percent of set point, before pipes
5 seconds 12 to 57 seconds
Installed cost

Same study, 2010 prices
About $1,000 $2,500 to $3,350
Expected life

DOE, modeled from surveys
About 15 years About 20 years, unverified
Hard water

PNNL review, 2013
Scale can shorten life; draining helps Softening or regular deliming may be needed
Power

Study units; DOE notes some tanks vary
Those needed none Needs an outlet

Tankless saves energy and costs far more to install. Whether it pays depends on prices, hard water and how long it lasts, and the last of those has not been measured.

Bohac et al., Center for Energy and Environment, 2010; US DOE, 89 FR 37778 (2024) and 89 FR 105188 (2024, rule later withdrawn; analysis only); Widder and Baechler, PNNL-22921, 2013.

Standby loss is the heart of the saving. A tank keeps water hot all day, and on a day with no use the study’s tank burned 16.6 kBtu to do that, against 0.6 for the average tankless unit. Reader claims about never heating water you are not using are right in direction.

Ratings run ahead of reality for both types. Bohac found rated efficiency over-predicted measured efficiency by 14 percentage points for tanks and 9 for tankless.

An NREL model by Jay Burch and colleagues showed one reason: a realistic pattern of small draws cut a unit’s efficiency from 0.81 to 0.74.

Today’s labels use a newer scale, the Uniform Energy Factor, where higher is better. ENERGY STAR requires at least 0.95 for gas tankless, 0.81 to 0.86 for gas tanks, and 3.30 for a standard integrated heat pump tank.

Those are floors for a label and not field results, so expect the home figure to be lower.

Does It Pay for Itself?

The honest answer is that it depends on numbers nobody can promise. Bohac’s paybacks were 20 to 40 years, at 2010 energy prices and contractor costs. Its authors add that if a tankless unit really lasts 20 years against a shorter-lived tank, the simple payback falls to 7 to 27 years.

Readers reported both quick and impossible paybacks, and both may be true of their own quotes. Pacific Northwest National Laboratory says the payback period “will vary widely.”

We have no current field-measured payback, and prices have changed since 2010, so treat 20 to 40 years as the shape of the problem and not as today’s figure.

Do the sum on your own quotes. Take the extra installed cost, divide it by the yearly energy saving your utility rates give, and compare that with the unit’s life.

Bohac’s interviewed contractors put a whole-house retrofit at $2,000 to $5,000 in 2010, against about $1,000 for a tank, and the study notes that gas lines sometimes need upsizing.

DOE’s rule documents carry newer installed-cost tables, but they cannot be subtracted to give a difference. They use different dollar years and different groups of consumers, and the tankless rule was later withdrawn. We have not printed a current gap for that reason.

How Long Do They Last?

This is the softest number in the argument. DOE uses about 15 years for storage heaters and about 20 for tankless units. Both are estimated from survey data on appliance ages and past shipments, not from following failures. Commenters on the storage rule argued for 13 years, and said these are “calculated estimates”.

Bohac’s report called the 20-year tankless figure a manufacturers’ claim and said there “has not been enough information collected to verify this lifetime.” Pacific Northwest puts water heater life generally at 8 to 20 years. Readers reported tankless units running for decades, and those are real reports from people whose units survived.

Hard Water, and the Softener Catch

Hard water is what can take the tankless advantage back. “For tankless water heaters, current research suggests that artificial water softening may be required in most hard water conditions,” the Pacific Northwest review says, because scaling can cut lifetime to under two years in extremely hard water unless deliming and manufacturer maintenance are kept up.

That is the extreme case, and readers on hard water reported long service with regular descaling. Both can be true. It does mean a tankless heater on hard water comes with a job attached.

Gas tanks are not immune: the same review says scale can cut gas heater efficiency by up to 10 percent and lifetime by 25 to 40 percent in extreme cases.

A softener is not a free fix for a tank. The review says soft water, especially from salt-based softeners, can reduce tank life by 50 percent or more, and it calls a softener a last resort for gas tanks.

If you soften, it advises checking the anode rod yearly or fitting a powered anode. Your water utility can tell you how hard your water is.

Maintenance is the quiet decider. The review says regular anode inspection “does not appear to be a common practice”, and that heaters are failing early as a result. A reader who said nobody they know flushes a tank was describing the same thing.

Is the Hot Water Really Endless, and How Long Is the Wait?

Mostly yes, within a flow limit. Bohac says tankless units can give endless hot water at a fairly high flow rate. Residents in the study rated “not running out” far higher for tankless than tank, though very few households answered.

The ENERGY STAR test for gas units is 2.8 gallons a minute or more over a 67°F rise.

The wait is real, and it adds to the pipes. In Bohac’s lab, tankless units took 12 to 57 seconds to reach 95 percent of set point, against 5 seconds for a tank, and the authors note that pipe delivery time “must be added”.

Burch lists a firing delay of 3 to 10 seconds, and a minimum flow of 0.5 to 0.8 gallons per minute.

That minimum explains a reader’s complaint about faucets that run cold at a trickle. A California Building America study of seven homes found 7.2 percent of tankless flow arrived below 105°F, against 1.2 percent for tanks.

The “cold water sandwich”, where a short burst of cold follows leftover hot water, is defined in Bohac and has not been measured for size, in anything we read.

A reader was right that most of the wait is the pipe, under either heater. Gary Klein’s arithmetic for a single-story 1,500-square-foot home gives 1 to 1.5 minutes to the furthest fixture at 2 gallons a minute. Lawrence Berkeley National Laboratory saw about a minute before showers reached temperature, in a tiny five-shower pilot.

Does tankless make people use more hot water? Bohac found no significant change at six of seven sites. The California study found hot water loads up 8 percent on average, with fewer, longer draws. Neither is large.

A 2011 Berkeley Lab review of 142 houses put typical use at about 50 gallons a day, with most homes between 20 and 80.

Power Cuts

Readers valued tanks in outages, and the evidence is only partial. Bohac’s natural-draft tanks needed no electricity, while its tankless units needed an outlet and drew 50 to 80 watts running.

DOE confirms electric heaters stop without power, and notes that some gas water heaters need electricity too. So check the model you are buying before assuming either way.

If You Heat Water With Electricity

Electric tankless is the weakest evidence here. We have no field study of its panel load or savings to cite.

Burch’s paper notes that gas has more to gain, because electric tanks already run at a far higher rated efficiency, and DOE says panel upgrades can run to about $750 to $2,000, citing a cost website.

A heat pump tank is the alternative most readers raised. A DOE Building America case study of 14 Northeast units measured efficiency well above an electric element, with projected water heating savings of 36 to 63 percent, at $1,900 to $3,600 installed in 2013. Pacific Northwest says one can save up to 62 percent over a typical electric tank.

The limits are specific. The same case study found recovery far slower than an electric element, about 8 gallons an hour against more than 20, and confined spaces cut efficiency by about 16 percent.

It also says natural gas remains the least-cost storage option on annualized cost, so a gas home does not automatically gain by switching.

New 120-volt units avoid a dedicated circuit. A Pacific Northwest project in 22 New Orleans homes completed installs without changing electrical infrastructure, although about 25 percent of visited homes had a missing, weak or unsafe outlet.

These units are larger, and the slides give no efficiency results. For where else electricity goes, see why your bill went up.

Questions to Ask Before You Sign

Ask for the whole job in writing. For tankless, that means the venting, any gas line upsizing, and the outlet, since Rinnai’s comments to DOE show venting costs alone are disputed. Ask what maintenance the warranty requires, and whether your water hardness affects it, given what Pacific Northwest says about scale.

For a tank, ask whether the unit has a replaceable anode and what the warranty covers, and compare first-hour ratings if the household showers back to back.

For a heat pump tank, ask about the space around it and the circuit it needs. Any contractor should pull whatever permit your area requires, and those rules vary locally.

If simple and cheap is the goal, readers mostly advised replacing a failed tank like for like, and nothing here argues against it.

If you run out of hot water often and have soft or treated water, tankless earns its case. Another upgrade where the gain depends on the house is covered in white roofs.

Local Regulations and Safety Advisory

Your local building department can say which permits and inspections apply. This article is general information, not legal or professional safety advice.

Authorities to consult:

  • Local building department
  • Licensed gas professional
  • Licensed electrician

Leave gas and electrical work to licensed professionals, and call emergency services if there is an immediate hazard.

What Remains to Be Explored

We searched for a current field-measured payback, measured tankless lifetimes, and a retrofit field study newer than about 2013, and have none to cite. The cold water sandwich has never been sized in anything we read. No source we read states directly how tankless units behave in an outage.

Electric tankless panel load, tankless output against very cold inlet water, and gas line upsizing rates also lack citable measurements. A new multi-year field study, across hard and soft water and using current labels, would settle most of this. Until then, every confident number in this argument deserves a second look, including ours.

Sources

More in